FLIR A315 (60Hz)

The FLIR A315 (48001-1101) Thermal Imaging Camera offers an affordable and accurate temperature measurement solution for anyone who needs to solve problems that do not call for the highest speed or reaction and who uses a PC

RHP International will be closed Thursday, November 24th and Friday November 25th,
due to the Thanksgiving Holiday weekend and returning Monday, November 28th.
FLIR A315 (60Hz)

FLIR A315 (60Hz)

Request Quote
1-888-919-2263
Manufacturer: FLIR Systems
Model: 48001-1101
Available
Product Highlights
  • IP Thermography Camera
  • 320x240 Resolution
  • 25°(H) × 18.8°(V) FOV
  • Multiple Lens Options
  • GigE Vision™ & GenICam™ Compliant

FLIR A315 18mm Thermal Imaging Camera

The FLIR A315 18mm thermal imaging camera offers an affordable and accurate temperature measurement for a variety of applications where network capabilities and compliance with network protocols are of importance. The FLIR A315 18mm thermal imaging camera comes with a 18mm standard lens providing a 25°×19° field of view and 320×240 resolution.

The FLIR A315 18mm features GigE Vision and GenICam compliance, which makes it plug-and-play ready when used with software packages such as IMAQ Vision and Halcon.

The FLIR A315 18mm is used in several industries where infrared and thermal measurement are required. Automotive car-seat heating, engine manufacturing, food processing, and electronics are just a few of the industries in which the FLIR A315 18mm is utilized.


Click to view larger image

FLIR A315 18mm Key Features

  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100Mbps Ethernet (100m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
  • 16-bit Image Streaming
  • GigE Vision™ Standard Compatability
  • GenICam™ Protocol Support

 

 

The FLIR A315 thermal imaging camera offers several different lens options

Model FLIR A315 90°
(T197411)
FLIR A315 45°
(1196960)
FLIR A315 18°
(48001-1101)
FLIR A315 15°
(1196961)
FLIR A315 6°
(T197407)
FLIR A315
Close-up 1x

(T197415)
FLIR A315
Close-up 2x

(T197214)
FLIR A315
Close-up 4x
(T197215)
Resolution 320×240
Resolution
320×240
Resolution
320×240
Resolution
320×240
Resolution
320×240
Resolution
320×240
Resolution
320×240
Resolution
320×240
Resolution
Field of View 90°×73° 45°×33.8° 25° x 18.8° 15°×11.25° 6°×4.5° 8×6 mm 16×12 mm 32×24 mm
Focal Length 4 mm
(0.157 in.)
9.66 mm
(0.38 in.)
18 mm
(0.7 in.)
30.38 mm
(1.2 in.)
76 mm
(3.0 in.)
18.2 mm
(0.72 in.)
37 mm
(1.5 in.)
73 mm
(2.9 in.)
Depth of Field - - - - - ±0.15 mm ±0.4 mm ±2.0 mm
Option * T197000; High temp. option +1200°C/+2192°F also available for FLIR A3xx Series

 

Technical Specs Lens Options Accessories Request Quote

Medical

Infrared thermography is based on analysis of skin surface temperatures as a reflection of normal or abnormal human physiology using a high performance infrared camera.

Safety

In oil/gas production, power generation or distribution there is a need to prevent and detect fires fast and automatically. A fix mounted infrared camera can be installed discretely and almost anywhere to monitor your business.

Education

FLIR infrared cameras are being used in university laboratories where high-end academic and applied research is on-going in a wide range of disciplines.

Veterinarian

An animal's body creates heat that fluctuates throughout the body depending on blood flow. The body's recognition of injury and a subsequent increase in blood flow can happen even before the animal shows signs of pain, and other conditions.

Automation

For the automotive industry the ability to continuously and automatically ensure quality is of great importance. A fix mounted infrared camera can be installed almost anywhere to monitor your production process.

Manufacturing

IR cameras made by FLIR have become indispensible tools for many engineering disciplines, particularly in advanced product development.

Compare Models Request Quote

Please Log In or Sign Up to access downloads

FLIR A300

FLIR A310

FLIR A315

FLIR A615

320×240 Resolution 320×240 Resolution 320×240 Resolution 640×480 Resolution
MPEG-4 Streaming Video Extensive Analasys Functions 16-bit Image Streaming 16-bit Image Streaming
Composite Video Out Built-in Alarm Functions GigE Vision™ Standard Compatabiltity GigE Vision™ Standard Compatability
Most Affordable Ethernet/IP Connectivity GenICam™ Protocol Support GenICam™ Protocol Support
  Digital Inputs/Outputs Digital Inputs/Outputs Digital Inputs/Outputs
      Windowing Mode

 

  FLIR A315 FLIR A615
Imaging and optical data
Spatial resolution (IFOV) 1.36 mrad 0.69 mrad
Focal length 18 mm 24.5 mm
F-number 1.3 1.0
Image frequency 60 Hz 50 Hz (100/200 Hz with windowing)
     
Detector data
IR resolution 320 × 240 pixels 640 × 480 pixels
Detector pitch 25 μm 17 μm
Detector time constant Typical 12 ms Typical 8 ms
     
Measurement
Object temperature range –20 to +120°C
0 to +350°C
-20 to +150°C
+100 to +650°C
+300 to +2000°C
     
USB
USB N/A Control and image
USB, standard N/A USB 2 HS
USB, connector type N/A USB Mini-B
USB, communication N/A TCP/IP socket-based FLIR proprietary
USB, image streaming N/A 16-bit 640 × 480 pixels at 25 Hz
16-bit 640 × 240 pixels at 50 Hz
16-bit 640 × 120 pixels at 100 Hz
- Signal linear
- Temperature linear
- Radiometric
USB, protocols N/A TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
     
Ethernet
Ethernet, image streaming 16-bit 320 × 240 pixels at 60 Hz
- Signal linear
- Temperature linear
- Radiometric
GigE Vision and GenICam compatible
16-bit 640 × 480 pixels at 50 Hz
16-bit 640 × 240 pixels at 100 Hz
16-bit 640 × 120 pixels at 200 Hz
- Signal linear
- Temperature linear
- Radiometric
GigE Vision and GenICam compatible

 

  FLIR A315 - Standard FLIR A315f - Environmental housing FLIR A615 - Standard
Environmental data
Operating temperature range –15°C to +50°C –25°C to +50°C –15°C to +50°C
Encapsulation IP 40 (IEC 60529) IP 66 (IEC 60529) IP 40 (IEC 60529)
Bump 25 g (IEC 60068-2-29) 5 g, 11 ms (IEC 60068-2-27) 25 g (IEC 60068-2-29)
       
Physical data
Weight 0.7 kg 5 kg 0.9 kg
Camera size
(L × W × H)
170 × 70 × 70 mm 460 × 140 × 150 mm 216 x 73 x 75 mm
Tripod mounting UNC ¼"-20 (on three sides) N/A UNC ¼"-20 (on three sides)
Base mounting 2 × M4 thread mounting holes (on three sides) TBA 2 × M4 thread mounting holes (on three sides)
       
System features
Automatic heaters N/A Clears ice from window N/A

General


Imaging and optical data
Field of view (FOV) / Minimum focus distance 25° × 18.8° / 0.4 m
Lens identification Automatic
Thermal sensitivity/NETD < 0.05°C @ +30°C / 50 mK
Focus Automatic or manual (built in motor)
   
Detector data
Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5–13 μm
   
Measurement
Accuracy ±2°C or ±2% of reading
   
Measurement analysis
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global object parameters
   
Ethernet
Ethernet Control and image
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, type Gigabit Ethernet
Ethernet, communication TCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
   
Digital input/output
Digital input 2 opto-isolated, 10–30 VDC
Digital output, purpose Output to ext. device (programmatically set)
Digital output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 12/24 VDC, max 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Digital input, purpose Image tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
   
Power system
External power operation 12/24 VDC, 24 W absolute max
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
   
Digital input/output
Digital input, purpose Image tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
   
Environmental data
Storage temperature range –40°C to +70°C
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
EMC • EN 61000-6-2:2001 (Immunity)
• EN 61000-6-3:2001 (Emission)
• FCC 47 CFR Part 15 Class B (Emission)
Vibration 2 g (IEC 60068-2-6)
   
Physical data
Housing material Aluminium
   
Scope of delivery
Hard transport case or cardboard box, Infrared camera with lens, Utility CD-ROM, Calibration certificate, Ethernet™ cable, USB cable (FLIR A615), Mains cable, Power cable (pig-tailed), Power supply, Printed Getting Started Guide, Printed Important Information Guide, User documentation CD-ROM, Warranty extension card or Registration card, 6-pole screw terminal (mounted on camera)

Lenses

Extended measurement ranges

Power

Cables

Transport, hard cases & other

Miscellaneous

Software

Services

The FLIR A-Series Lens Options

Please note: Adding a new lens requires factory re-calibration

Model IR lens, 4mm (90°)
(T197411)
IR lens, f=10mm, (45°)
(1196960)
IR lens, f=30mm, (15°)
(1196961)
IR lens, 76mm (6°)
(T197407)
Close-up 1× (25µm)
(T197415)
Close-up 2× (50µm)
(T197214)
Close-up 4× (100µm)
(T197215)
Price $3,095 $1,050 $1,325 $6,250 $4,725 $3,675 $2,625
Field of View 90°×73° 45°×33.8° 15°×11.25°
6°×4.5° 8×6 mm 16×12 mm 32×24 mm
Magnifying Factor-- - -
Working Distance - - - - 20 mm 33 mm 79 mm
Minimum Focus Distance 40 mm
(1.57 in.)
0.20 m
(0.66 ft.)
1.2 m
(3.93 ft.)
4 m
(13.11 ft.)
- - -
Depth of Field - - - - ±0.15 mm ±0.4 mm ±2.0 mm
Focal Length 4 mm
(0.157 in.)
9.66 mm
(0.38 in.)
30.38 mm
(1.2 in.)
76 mm
(3.0 in.)
18.2 mm
(0.72 in.)
37 mm
(1.5 in.)
73 mm
(2.9 in.)
Spatial Resolution (IFOV)6.3 mrad

2.59 mrad

0.82 mrad 0.33 mrad25 µm 50 µm 100 µm
F-number 1.3 1.3 1.3 1.3 1.3 1.3 1.3
Number of Lenses 3 (3asph) - - 3 (3 asph) 3 (3 asph) 2 (2 asph) 2 (2 asph)
MTF @ 70% of FOVNormal requirements (52%)--Normal requirements (52%)Normal requirements (52%)Normal requirements (52%)Normal requirements (52%)
Distortion 5% - - 3% 3% 3% 3%
Weight Lens: 0.262 kg (0.578 lb.)
Support: 0.048 kg (0.106 lb.)
0.105 kg (0.231 lb.), incl. two lens caps 0.092 kg (0.203 lb.), incl. two lens caps Lens: 0.328 kg (0.723 lb.)
Support: 0.15 kg (0.331 lb.)
0.38 kg
(0.83 lb.)
0.11 kg
(0.24 lb.)
0.11 kg
(0.24 lb.)
Size (L x D) 90×60 mm (3.54×2.36 in.), excluding support 38×47 mm (1.5×1.9 in.) 24×58 mm (1.0×2.3 in.) 106×89 mm (4.17×3.48 in.), excluding support 167×60 mm 35.2×55 mm 35.2×55 mm
IncludesLens, Lens Case, Mounting SupportLens, Lens CaseLens, Lens CaseLens, Lens Case, Mounting Support Lens, Lens Case, Mounting Support Lens, Lens Case Lens, Lens Case