Available Accessories
- Compact
- 45°(H) × 37°(V) FoV
- 17 µm Pitch
- F#/1.25
- GigE Vision and GenICam compliant.
- GigE Vision lockable connector.
- PoE (power over Ethernet).
- 8-bit 640 × 512 pixel images streamed at 30 Hz, signal linear
- 14-bit 640 × 512 pixel images streamed at 30 Hz, signal and temperature linear
- SKU: 75013-0101
PRICE INCREASES IN:
Available Options
EXPORT CONTROLLED PRODUCT :
FLIR 320x240 60Hz and 30Hz Fast-Video and 640x480 30Hz Fast-Video (>9Hz) uncooled LWIR Thermal Camera Core products are export controlled and require validated export licenses from the U.S. Department of Commerce prior to export or re-export outside of the United States to certain countries.
Strategic Trade Authorized (STA) Countries are an exception. In circumstances whereby "RHP International" delivers a camera to a customer in the U.S. who intends to export or re-export the FLIR camera outside of the United States, whether or not the camera is integrated into another product, it is the customer’s responsibility to apply for the required export license from the appropriate department of the U.S. government. Diversion contrary to U.S. law is prohibited.
Click the link below for a list of STA countries and more Export information.
The Export Conditions page details information regarding what countries thermal cameras can be exported to.
FLIR A65 13mm (30 Hz) - 45° FoV Thermal Imaging Camera
IR TEMPERATURE SENSOR
The FLIR A65 13mm (30 Hz) is a thermal imaging temperature sensor for process control/quality assurance, fire prevention, and condition monitoring that offers comprehensive visual temperature monitoring. The A65 integrates seamlessly into existing systems and provides temperature linear output through GenICam™ compliant software.
Advanced Thermal Imaging For Condition Monitoring

AFFORDABLE AND COMPACT
At just 4.1 × 1.9 × 1.8 in, the A65 brings thermal imaging to your smallest spaces at an affordable price.

PLUG-AND-PLAY
Easy setup thanks to GigE Vision and GenICam compliance and GigE Vision lockable connector.

CONNECT MULTIPLE CAMERAS
Synchronize between multiple cameras for greater coverage and communication, or for stereoscopic applications.
Temperature Sensing With the Advantage of Image Quality
The FLIR A65 produces stunning 327,680 pixel thermal images that are low noise, and can show temperature differences as small as 50 mK. This allows you to easily track temperature changes, whether your application is process control/quality assurance, condition monitoring, or fire prevention.

VISUALIZE HEAT
These non-contact temperature sensors are enhanced with thermal imaging
• Detect temperature differences as small as 50 mK
• Choose the right field of view for your measurement
area, from wide (90°) to narrow (6.2°)
• Measures accurately in conditions up to 140°F (60°C)

COMMUNICATE DATA SEAMLESSLY
Stream temperature linear output through GenICam™ compliant software
• Integrate easily with Cognex, National Instruments,
and other top machine vision systems
• Stream thermal images at up to 60 Hz directly to your
system, for instant data analysis
• Synchronize cameras for stereoscopic applications

DESIGNED TO FIT YOUR APPLICATIONS
Get more out of your data with advanced analysis tools
• Compact size makes for easy installation in electrical
cabinets and other small spaces.
• Offering the stability of a GigE Vision lockable connector, and the flexibility of Power over Ethernet (PoE)
• Ideal for any environment, the cameras’ robust design
can withstand harsh conditions
OVERVIEW | |
Spectral Band | LWIR | 7.5 µm – 13 µm |
Accuracy | ±5°C (±9°F) or ±5% of reading |
Field of View | 45°(H) × 37°(V) (Horizontal x Vertical) |
Resolution | 640 × 512 pixels |
Packaging Size | 295 x 200 x 105 mm (11.6 x 7.9 x 4.1 in.) |
Sensitivity/NEdT | < 0.05°C @ 30°C (86°F) / 50 mK |
Temperature Range | -25°C to 135°C (-13 to 275°F) / –40°C to 550°C (-40 to 1022°F) |
Detector Type | Focal plane array (FPA), uncooled VOX microbolometer |
f-number | 1.25 |
Focal Length | 13 mm (0.5 in.) |
Weight | 0.200 kg (0.44 lb.) |
Dimensions (L x W x H) | 106 × 40 × 43 mm (4.2 × 1.6 × 1.7 in.) |
FLIR Screen - EST Mode | No |
Housing material | Magnesium and aluminum |
CONNECTIONS & COMMUNICATIONS | |
Digital I/O connector type | 12-pole M12 connector (shared with Digital Synchronization and External power) |
Digital I/O isolation voltage | 500 VRMS |
Digital input purpose | General Purpose |
Digital Inputs | 1× opto-isolated, "0" <1.2 VDC, "1" = 2–25 VDC. |
Digital Output Purpose | General purpose output to ext. device (programmatically set) |
Digital Outputs | 1× opto-isolated, 2–40 VDC, max 185 mA |
Ethernet | Control and image |
Ethernet Communication | GigE Vision ver. 1.2 Client API GenICam compliant |
Ethernet Image Streaming | 8-bit monochrome @ 60 Hz Signal linear/ DDE Automatic/ Manual Flip H&V 14-bit 320 × 256 pixels @ 60 Hz Signal linear/ DDE Temperature linear GigE Vision and GenICam compatible |
Ethernet Connector Type | RJ-45 |
Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 0 Power |
Ethernet Protocols | TCP, UDP, ICMP, IGMP, DHCP, GigEVision |
Ethernet Standard | IEEE 802.3 |
Ethernet Type | Gigabit Ethernet |
Connection Type | 12-pole M12 connector (shared with Digital I/O and External power) |
Synchronization in | 1×, non-isolated |
Synchronization in - purpose | Frame synchronization in to control camera |
Synchronization in - type | LVC Buffer @3.3V, "0" <0.8 V, "1" >2.0 V. |
Synchronization out | 1×, non-isolated |
Synchronization out - purpose | Frame sync out to control another Ax5 camera |
Synchronization Out - type | LVC Buffer @ 3.3V, "0"=24 MA max, "1"= –24 mA max. |
IMAGING & OPTICAL | |
Detector Pitch | 17 µm |
Detector Time Constant | Typical 12 ms |
Focus | Fixed |
Image Frequency | 30 Hz |
Spatial resolution (IFoV) | 1.31 mrad |
INTERFACE (ELECTRICAL) | |
Supply voltage | 2–40 VDC, max 200 mA |
MEASUREMENT & ANALYSIS | |
External Optics & Windows Correction | Automatic, based on input of optics/window transmission and temperature |
Measurement Corrections | Global object parameters |
Optics Transmission Correction | Automatic, based on signals from internal sensors |
Reflected apparent temperature correction | Automatic, based on input of reflected temperature |
ENVIRONMENTAL | |
Atmospheric transmission correction | Automatic, based on inputs for distance, atmospheric temperature and relative humidity |
EMC | EN 61000-6-2 (Immunity) EN 61000-6-3 (Emission) FCC 47 CFR Part 15 Class B (Emission) |
Emissivity Correction | Variable from 0.5 to 1.0 |
Operating Temperature Range | –15°C to 50°C (5°F to 122°F) The operating temperature range assumes that the camera is mounted on the base support (included in the package) or a similar type of heat-sink. |
Encapsulation | IP 40 (IEC 60529) with base support mounted |
Storage Temperature Range | –40°C to 70°C (–40°F to 158°F) |
Humidity (Operating and Storage) | IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F) |
Shock | 25 g (IEC 60068-2-27) |
Tripod Mounting | UNC ¼"-20 (on three sides) |
Vibration | 2 g (IEC 60068-2-6 & MIL-STD810G) |
POWER | |
External Power Operation | 12/24 VDC, < 3.5 W nominal < 6.0 W absolute max |
Input Voltage | Allowed range 10–30 VDC |
MECHANICAL | |
Base Mounting | 4 × M3 thread mounting holes (bottom) |
FLIR Boson Frequently Asked Questions
The table below shows sensitivity as a function of configuration, normalized to f/1.0. The specified requirements are when operating in the high-gain state at 20C, with the averager disabled, in free-running mode, imaging a 30C background. (NEDT values with averager enabled are approximately 20% lower than shown in the table.)
For the 320 configuration, NEDT requirements in low-gain state are 250% of the values shown in Table. (Only industrial and professional-grade configurations provide a low-gain state.)
For the 640 configuration, NEDT requirements in low-gain state 300% of the values shown in the table.
TEMPORAL NEDT IN HIGH-GAIN STATE
NEDT values shown are acceptance-test limits representing the lensless configuration with an f/1.0 aperture installed. With a lens installed, test limits are scaled by (f/#)2 / τ
The FLIR Boson requires at least one interface board to allow Power and acquire Video from it's high-density connector.
The most popular board in our product list is the Low Profile VPC module. It allows for power input, streaming USB and composite analog video as well as controlling the cameras settings.
A complete list of accessories are available at: https://www.oemcameras.com/boson_accessories.
To choose the proper FOV and resolution we recommend the Field of View tool here: https://www.oemcameras.com/fov_tool
For video acquisition and control you will need to use the Boson Controller GUI 3.0 available from Teledyne FLIR.
With the RHP Boson interface boards, you may also use the RHP Boson GUI.
Note that these calculations become less accurate at very close ranges, or for very wide field of view lenses.
All Boson thermal camera modules feature FLIR infrared video processing architecture, noise reduction filters, and local-area contrast, utilizing a high sensitivity 12-micron pixel pitch detector that provides high-resolution thermal imaging in a small, lightweight, and low-power package. The image processing capabilities accommodate industry-standard communication interfaces, including visible CMOS and USB.
Boson Radiometric cameras bring absolute temperature measurement capabilities for quantitative assessment and analysis across commercial and industrial uses. The Boson Radiometric models feature radiometric temperature measurement, meaning the cameras capture the temperature data of every pixel in every frame of a scene. This makes them ideal for implementation with unmanned aerial systems, firefighting, automotive, security, surveillance, and industrial inspection.
Configurations of Boson which are radiometric capable feature the ability to output a “temperature stable” output or a “temperature linear” output. In the former case, the 16b output is intended to be linear with input flux (i.e. target irradiance) and independent of the camera’s own temperature. In the latter case, the input flux is translated to absolute temperature (Kelvin). That is, the output is linear with scene temperature. For temp-linear output, parameters such as target emissivity atmospheric transmission can be adjusted to reflect current imaging conditions.
Standard Boson or Radiometric Bosons
Radiometry Disabled (T-linear Enable/Disable has no effect on output): 16b output varies with both scene flux and camera temperature.
Radiometric Bosons
Radiometry Enabled, T-linear Disabled:
Temperature-stable output: 16b output value is intended to be proportional to scene-flux only and independent of the camera temperature. That is, when imaging a given scene, the output image is stable even if the camera’s temperature varies. By comparison, output varies significantly with camera temperature when radiometry is disabled.
Radiometry Enabled, T-linear Enabled:
Temperature-linear output: 16b output value is intended to be directly proportional to scene temperature. In high-gain state, the 16b output value corresponds to scene-temperature in Kelvin multiplied by 100, and in low-gain state, it corresponds to Kelvin multiplied by 50. For example, expected output in high-gain state when imaging a 20C BB is [(20C + 273.15)] * 100 = 29315. In practice, radiometric error prevents an output which corresponds perfectly with scene temperature.
Radiometric accuracy provides ±5 °C (±8 °F) or ±5% temperature measurement accuracy and include a Spot Meter Accuracy software feature that provides an assessment of how accurate a given temperature measurement appears in the scene.
Some of the benefits of advanced radiometric cameras include:
- Improved accuracy (typical performance on the order of +5 Co or 5% in high-gain state, varying slightly across the full operating temperature range)
- Moveable and resizable spot-meter (coordinates can be user-selectable to any location on the array)
- Additional spot-meter data (average, standard deviation, minimum, and maximum value)
- Digital data linear in scene temperature (in real-time operation, the pixel values in the digital data correspond to the temperature of the scene)
- Detailed temperature information (users derive temperature information per pixel from objects in the scene)
- Temperature precision (allows external scene parameters to be compensated for emissivity– a measure of the efficiency of a surface to emit thermal energy relative to a perfect blackbody source– and window transmission, to more accurately determine temperature)
- Image Metric Feature (enables users to query the camera for scene temperature data via serial command, such as maximum, minimum, and standard deviation for user-defined regions).